The purpose of this study was to examine the heat stress effects of three protective clothing ensembles: (1) protective apron over cloth coveralls including full face negative pressure respirator (APRON); (2) the apron over cloth coveralls with respirator plus protective pants (APRON+PANTS); and (3) protective coveralls over cloth coveralls with respirator (PROTECTIVE COVERALLS). In addition, there was a no-respirator ensemble (PROTECTIVE COVERALLS-noR), and WORK CLOTHES as a reference ensemble. Four acclimatized male participants completed a full set of five trials, and two of the participants repeated the full set. The progressive heat stress protocol was used to find the critical WBGT (WBGTcrit) and apparent total evaporative resistance (Re,T,a) at the upper limit of thermal equilibrium. The results (WBGTcrit [°C-WBGT] and Re,T,a [kPa m2 W−1]) were WORK CLOTHES (35.5, 0.0115), APRON (31.6, 0.0179), APRON+PANTS (27.7, 0.0244), PROTECTIVE COVERALLS (25.9, 0.0290), and PROTECTIVE COVERALLS-noR (26.2, 0.0296). There were significant differences among the ensembles. Supporting previous studies, there was little evidence to suggest that the respirator contributed to heat stress.