2007 Volume 26 Issue 6 Pages 898-905
The aim of this study was to establish an objective and quantitative method of measuring occlusal contact areas. To this end, bite records were taken with a silicone impression material and a light transmission device was used to read the silicone impression material. To examine the effectiveness of this novel method, the occlusal contact area of the silicone impression material and its thickness limit of readable range were measured. Results of this study suggested that easy and highly accurate measurements of occlusal contact area could be obtained by selecting an optimal applied voltage of the light transmission device and an appropriate color of the silicone impression material.