International Journal of Fluid Machinery and Systems
Online ISSN : 1882-9554
ISSN-L : 1882-9554
Original Papers
Experimental Study on Internal Flow of a Mini Centrifugal Pump by PIV Measurement
Yulin WuHuijing YuanJie ShaoShuhong Liu
Author information
JOURNAL FREE ACCESS

2009 Volume 2 Issue 2 Pages 121-126

Details
Abstract

The internal flow field in a centrifugal pump working at the several flow conditions has been measured by using the particle image velocimetry (PIV) technique with the laser induced fluorescence (LIF) particles and the refractive index matched (RIM) facilities. The impeller of the centrifugal pump has an outlet diameter in 100mm, and consists of six two-dimensional curvature backward swept blades of constant thickness. Measured results give reliable flow patterns in the pump. It is obvious that application of LIF particle and RIM are the key methods to obtain the right PIV measured results in pump internal flow.

Content from these authors

This article cannot obtain the latest cited-by information.

© 2009 Turbomachinery Society of Japan, Korean Fluid Machinery Association, Chinese Society of Engineering Thermophysics, IAHR
Previous article Next article
feedback
Top