日本放射線技術学会雑誌
Online ISSN : 1881-4883
Print ISSN : 0369-4305
ISSN-L : 0369-4305
臨床技術
99mTc-ECD非侵襲的脳血流定量法(Brain Uptake Ratio)における入力関数の最適ROI設定位置の決定
井上 信哉甲 卓馬増永 新一郎相馬 努高木 昭浩細谷 徹夫吉岡 克則伊藤 茂樹
著者情報
ジャーナル フリー

2012 年 68 巻 3 号 p. 269-276

詳細
抄録

Determination of the input function for the 99mTc-ethyl cysteinate dimmer brain uptake ratio (99mTc-ECD BUR) method as a non-invasive quantitative measurement of cerebral blood flow measurement is of critical importance in order to improve the accuracy of this method. The input functions were experimentally obtained by setting the regions of interest (ROIs) in the ascending aorta, aortic arch, and descending aorta on the 49 chest RI-angio images. rCBFs by the BUR method with 3 input functions of the 6 cases were compared with those by the 123I-iodoamphetamine (IMP) continuous arterial blood sampling method in order to determine the best location for the ROI of the input function. The input function of the ascending aorta was higher than those of the aortic arch and the descending aorta. The input functions of the aortic arch and the descending aorta decreased due to the origin of the three branches of the right brachiocephalic artery, left subclavian artery, and left common carotid artery. A good correlation was found in the regional cerebral blood flow (rCBF) values between the 123I-IMP continuous arterial blood sampling method and the 99mTc-ECD BUR method with the input function of the ascending aorta. Therefore, the ascending aorta is the best location for the ROI of the input function for the 99mTc-ECD BUR method.

著者関連情報