Journal of Veterinary Medical Science
Online ISSN : 1347-7439
Print ISSN : 0916-7250
ISSN-L : 0916-7250
FULL PAPER
A New Method of Measuring the Transepidermal Water Loss (TEWL) of Dog Skin
Toru YOSHIHARAKenichiroh SHIMADAYasuyuki MOMOIKatsuhiko KONNOToshiroh IWASAKI
Author information
JOURNAL FREE ACCESS

2007 Volume 69 Issue 3 Pages 289-292

Details
Abstract

Human skin barrier function is evaluated by measuring transepidermal water loss (TEWL). However, this conventional method has not been applied to assess canine skin barrier function because the equipment is not suitable for dogs due to the effects of air turbulence resulting from movement of the subject and vapor from the subject's hair coat. The TEWL analyzer CC-01 was developed as a closed-chamber method device; this means that instead of using the open-chamber method, it has a ventilated chamber that uses dry air. TEWL values measured by CC-01 show less variability than those measured by the conventional method. An ambient temperature of 20-26°C is optimal for measurement with the CC-01, and humidity affects the length of measurement but not the values. The CC-01 may be more reliable for measurement of TEWL than the conventional methods and may give new insights in the evaluation of skin barrier function in dogs.

Content from these authors
© 2007 by the Japanese Society of Veterinary Science

この記事はクリエイティブ・コモンズ [表示 - 非営利 - 改変禁止 4.0 国際]ライセンスの下に提供されています。
https://creativecommons.org/licenses/by-nc-nd/4.0/deed.ja
Previous article Next article
feedback
Top