Quarterly Report of RTRI
Online ISSN : 1880-1765
Print ISSN : 0033-9008
ISSN-L : 0033-9008
PAPERS
Effects of Low Frequency Vibration on Train Motion Sickness
Hiroaki SUZUKIHiroaki SHIROTOKazuhiko TEZUKA
Author information
JOURNAL FREE ACCESS

2005 Volume 46 Issue 1 Pages 35-39

Details
Abstract

In order to identify the vibrational characteristics influencing motion sickness experienced on trains, a poll of approximately 4,000 commercial passengers was carried out and vibration measurements taken on each train involved. When the results were summarized, it was revealed that the ratio of passengers who felt motion sickness on tilting trains was higher than that on non-tilting trains. Low frequency lateral motions in the range 0.25 to 0.32 Hz highly influenced the degree of motion sickness. Unlike seasickness, vertical motion effects were not apparent and there was a wide variation in susceptibility to motion sickness, with data from women and young people showing them to be more susceptible. Traditional frequency weighting curves for evaluating vibrational discomfort were ineffective for motion sickness evaluation. Consequently, a new frequency weighting curve needed to be proposed.

Content from these authors
© 2005 by Railway Technical Research Institute
Previous article Next article
feedback