脳卒中の外科
Online ISSN : 1880-4683
Print ISSN : 0914-5508
ISSN-L : 0914-5508
原  著
内頸動脈瘤手術時の動脈損傷の対処
谷中 清之岡崎 匡雄鯨岡 裕司目黒 琴生松丸 祐司塚田 篤郎淺川 弘之上村 和也能勢 忠男
著者情報
ジャーナル フリー

2003 年 31 巻 1 号 p. 24-28

詳細
抄録

Aneurysms can produce large defects in the parent vessel if the aneurysm tears at the neck of the vessel. We present techniques used to repair a tear at the base of an aneurysm encountered during microsurgical clipping of a ruptured aneurysm.
The repair technique involved suturing and covering the aneurysm with an encircling aneurysm clip. A large tear had destroyed the vessel's tubular structure and therefore an encircling clip alone was insufficient for repair. Two microsuture stitches were placed on the tear, so that a split artery reformed a tubular structure. The temporary clip on the distal internal carotid artery was removed for a moment, allowing the retrograde blood flow to provide the counterforce necessary to maintain the vessel's tubular structure.
An encircling clip was then applied to cover the entire circumference of the lesion. Another technique involved placing needles over a tear and applying clips while avoiding parent artery stenosis. Placing a clip to cover an entire tear resulted in an arterial stenosis but just applying a clip was insufficient for repair. With this guiding needle method, a clip can adequately be placed without parent artery stenosis.
These methods required only a short occlusion time for arterial repair, thus helping avoid ischemic complications. These techniques are useful for repairing an aneurysmal tear at its base, especially if the tear is large.

著者関連情報
© 2003 一般社団法人 日本脳卒中の外科学会
前の記事 次の記事
feedback
Top